Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Emerg Med ; 66(2): 197-210, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38309979

RESUMO

BACKGROUND: Ocular emergencies comprise 2-3% of emergency department (ED) visits, with retinal detachment requiring emergency surgery. Two-dimensional ultrasound is a rapid bedside tool but is highly operator dependent. OBJECTIVE: We determined three-dimensional ultrasound (3DUS) feasibility, acceptability, and usability in eye pathology detection using the ophthalmologist examination as reference standard. METHODS: We performed a prospective, blinded cohort study of a 3DUS-enabling device in 30 eye clinic and ED patients with visual symptoms and calculated 3DUS performance characteristics. Two expert readers interpreted the 3DUS images for pathology. All participants completed surveys. RESULTS: 3DUS sensitivity was 0.81, specificity 0.73, positive predictive value 0.54, negative predictive value 0.91, and likelihood ratio (LR)+/LR- 3.03 and 0.26, respectively. Novice and expert sonographers had "substantial" agreement in correct diagnosis of abnormal vs. normal (κ = 0.68, 95% confidence interval 0.48-0.88). Most patients indicated that 3DUS is fast, comfortable, helps them understand their problem, and improves provider interaction/care, and all sonographers agreed; 4/5 sonographers felt confident performing ultrasound. Expert readers correctly identified an abnormal eye in 83/120 scans (76%) and correct diagnosis in 72/120 scans (65%), with no statistical difference between novice (79%; 69%) and expert (72%; 61%) sonographers (p = 0.39, p = 0.55), suggesting reduced operator dependence. Reader diagnosis confidence and image quality varied widely. Image acquisition times were fast for novice (mean 225 ± 83 s) and expert (201 ± 51) sonographers, with fast expert reader interpretation times (225 ± 136). CONCLUSIONS: A 3DUS-enabling device demonstrates a sensitivity of 0.81 and specificity of 0.73 for disease detection, fast image acquisition, and may reduce operator dependence for detecting emergent retinal pathologies. Further technological development is needed to improve diagnostic accuracy in identifying and characterizing retinal pathology.


Assuntos
Serviço Hospitalar de Emergência , Humanos , Estudos de Coortes , Estudos Prospectivos , Estudos de Viabilidade , Sensibilidade e Especificidade , Ultrassonografia/métodos
2.
PLoS Negl Trop Dis ; 13(12): e0007935, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31834923

RESUMO

OBJECTIVES: Although more than 1.8 million people survive snakebite envenomation each year, their recovery is understudied. Obtaining long-term follow-up is challenging in both high- and low-resource settings. The Patient-Specific Functional Scale (PSFS) is an easily administered, well-accepted patient-reported outcome that is validated for assessing limb recovery from snakebite envenomation. We studied whether the PSFS is valid and reliable when administered by telephone. METHODS: This is a secondary analysis of data from a randomized clinical trial. We analyzed the results of PSFS collected in-person on days 3, 7, 14, 21, and 28 and by telephone on days 10, 17, and 24. We assessed the following scale psychometric properties: (a) content validity (ceiling and floor effects), (b) internal structure and consistency (Cronbach's alpha), and (c) temporal and external validity using Intraclass Correlation Coefficient (ICC). Temporal stability was assessed using Spearman's correlation coefficient and agreement between adjacent in-person and telephonic assessments with Cohen's kappa. Bland Altman analysis was used to assess differential bias in low and high score results. RESULTS: Data from 74 patients were available for analysis. Floor effects were seen in the early post-injury time points (median: 3 (IQR: 0, 5) at 3 days post-enrollment) and ceiling effects in the late time points (median: 9 (IQR: 8, 10). Internal consistency was good to excellent with both in-person (Cronbach α: 0.91 (95%CI 0.88, 0.95)) and telephone administration (0.81 (0.73, 0.89). Temporal stability was also good (ICC: 0.83 (0.72, 0.89) in-person, 0.80 (0.68, 0.88) telephone). A strong linear correlation was found between in-person and telephone administration (Spearman's ρ: 0.83 (CI: 0.78, 0.84), consistency was assessed as excellent (Cohen's κ 0.81 (CI: 0.78, 0.84), and Bland Altman analysis showed no systematic bias. CONCLUSIONS: Telephone administration of the PSFS provides valid, reliable, and consistent data for the assessment of recovery from snakebite envenomation.


Assuntos
Entrevistas como Assunto/métodos , Mordeduras de Serpentes/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA